Reinventing hydraulics: more control, more efficiency, more future.
Hydronit CEO
Flexible hydraulic integration for more versatile power pack configurations
External manifolds and accessories expand the functionality of Hydronit power packs with modular, compact and easy-to-install solutions. From NG6 and NG3 manifold blocks to hand pumps, filters, spacer elements and mounting accessories, this range is designed to simplify integration and improve hydraulic circuit flexibility.
Whether the application requires additional control functions, manual emergency operation, filtration or more compact valve arrangements, Hydronit offers a complete system of external manifolds and accessories engineered to work seamlessly with its modular hydraulic power units.
NG6 modular manifolds
Hydronit offers standard NG6 (Cetop 3) modular manifold blocks with parallel or series connections, available with rear or lateral ports. These blocks can be stacked one above the other, making them ideal for building flexible hydraulic circuits with a compact footprint. Top manifold P and T ports can also be closed with simple BSP plugs when required.
Modular manifolds with integrated pilot operated check valves
For applications where load holding and circuit safety are essential, pilot operated check valves can be integrated directly into NG6 modular manifold blocks. This solution eliminates the need for an additional Cetop sandwich valve, helping reduce stack height, simplify assembly and keep the hydraulic layout more compact.
External hand pump manifolds
External hand pumps with 4 cc or 8.8 cc per stroke can be mounted between the central manifold and the Cetop 3 modular block. This makes them a practical solution for emergency actuation or manual backup functions. The lever can be rotated 360°, offering greater installation flexibility.
Filter manifolds
Hydronit also provides modular filter solutions for both pressure line and return line applications. These manifolds can be stacked under NG6 blocks, helping protect the hydraulic circuit, improve oil cleanliness and support longer component life. Compact and high-flow options are available depending on system requirements.
Base blocks and converters
Specific base blocks and converter plates make it possible to connect Hydronit modular stackable valves to conventional units and extend compatibility between PPC, PPM, NG6 and NG3 MICRO configurations. This expands design freedom and allows the use of different manifold systems according to the application.
NG3 MICRO manifolds
The NG3 MICRO range is an ultra-compact and cost-effective alternative to NG6 (Cetop 3), suitable for flows up to 15 l/min. It is especially useful where installation space is limited and a smaller manifold arrangement is preferred, while still maintaining good hydraulic flexibility.
Spacer and rotation manifolds
Spacer blocks and 90° rotation manifolds help solve installation constraints and improve valve positioning when larger motors are used or when the hydraulic layout needs a different orientation. These components are especially valuable in compact power pack assemblies where every millimetre matters.
Accessories for configuration completion
A full range of accessories is available to complete the configuration of the hydraulic power pack, including plugs, gauges, switches and additional connection components. This helps designers and assemblers build complete, ready-to-install hydraulic solutions starting from a modular logic.
Why choose Hydronit external manifolds and accessories
- Modular configuration freedom
The range allows more flexible hydraulic layouts, with stackable solutions that simplify system customization. - Compact integration
Manifolds, hand pumps, filters and accessories are designed to fit efficiently into compact hydraulic power pack assemblies. - Simplified installation
The components are engineered for quick assembly and compatibility with Hydronit modular systems. - More functions in less space
Integrated solutions, such as pilot operated check valves inside modular blocks, help reduce the number of separate parts. - Better adaptability
Spacer blocks, converters and rotation manifolds make it easier to solve layout and mounting constraints. - Reliable hydraulic performance
All components are developed to support stable operation, efficient flow management and long-term durability.
Designed for compact hydraulic systems in multiple industries
Hydronit external manifolds and accessories are suitable for industrial, mobile and marine applications where compactness, flexibility and ease of integration are essential. They help OEMs, system integrators and hydraulic distributors create more advanced power pack configurations for lifting systems, mobile machinery, material handling equipment, marine devices and many other hydraulic applications.
FAQ
Yes. Hydronit external hand pump manifolds are designed to provide manual emergency actuation and are available with different displacement options.
The central manifold exit face allows the mounting of two different block systems, fixed by 2x M8 bolts (normally used for NG6 Cetop 3 modular manifolds stacks) or 4x M6 bolts (for additional or special manifolds). The two types of bolt systems cannot be mixed on the same stack. To mount stackable directional valves or NG3 MICRO directional valves an adaptor plate is required. See section G for the relevant valve details.
NG3 MICRO is the right choice when the application requires a more compact and cost-effective solution, especially for lower flow rates and reduced installation space.
Whenever a big motor is mounted on the power pack. Normally the E60403004 spacer must be mounted below the stack of NG6 (Cetop 3) blocks with AC motors with frame 80 or higher and with DC motors frame 125 or higher
With UR (reversible pump circuits) central manifold, the exit ports are directly A and B instead of P and T. With differential area cylinders, when the bidirectional pump flow is outputting to the rod side port (let’s say it is B port), there will be more flow returning to A port, connected to the piston side of the cylinder, due to the cylinder differential area ratio. The function of this manifold is to discharge the extra flow to tank at nearly zero pressure, as this cannot be absorbed by the pump itself and should otherwise flow throught the relief valve causing overheating and counterpressures.